Why Solar Quotations Differ So Much, and Why a Bigger Inverter Is Not Always Better
Two solar quotations for the same house can differ by thousands of ringgit. A worked sizing example shows where the difference comes from and what to ask before you compare prices.
Ask three companies to quote solar for the same house and you may get three system sizes and three prices. That is not always a sign that someone is overcharging. More often, each quotation rests on different design assumptions, and those assumptions are rarely written on the page.
Jarvis Ling, a director of AeanesDaT, has written a series of plain explanations of how a system is sized. This article follows his method with one worked example, so you can see where the differences come from.
Start with the bill, not the panel
A system should be sized from your electricity use. In the example, a household uses an average of 993 kWh a month.
- Choose a design basis. The example designs for 75% of average use: about 745 kWh a month, or 24.8 kWh a day.
- Divide by the sun you can expect. Using 3.5 peak sun hours a day, a figure taken from Global Solar Atlas for the example site, the array needs about 7.1 kWp before losses.
- Allow for real-world losses. Heat, cable losses, dust, inverter efficiency and ageing all reduce output. The example applies a design factor of 1.35, which gives about 9.6 kWp. Designers commonly use a factor somewhere between 1.2 and 1.4.
- Round to whole modules. With 620 Wp modules, that is 16 modules, or 9.92 kWp.
Change any one of those inputs and the answer moves. A designer who uses a factor of 1.2 instead of 1.35 arrives at about 8.5 kWp for the same house. Neither figure is dishonest, but they are not the same product, and they will not carry the same price.
These numbers are an illustration of the method. They are not a forecast for your home.
The bill gives the target. The roof gives the limit.
The calculation above is only preliminary sizing. It says nothing yet about your roof. A proper design still has to check:
- which way the roof faces and how steeply it is pitched
- shading from trees, neighbouring buildings, water tanks and parapets through the day
- usable roof area and how the modules can be laid out
- how modules are grouped into strings, and how those strings match the inverter's inputs
- the roof structure, and the cable route down to the distribution board
A quotation prepared from a bill alone, without anyone looking at the roof, is an estimate. It can be a useful one, but it should be labelled as an estimate.
kWp and kW are different numbers
Quotations often mix two units. kWp is the rated output of the modules on the roof, on the DC side. kW, sometimes written kWac, is the rated output of the inverter, on the AC side that feeds your home.
The two are usually not equal, and they do not need to be. Modules seldom produce their full rated output in real conditions, so designers often install slightly more module capacity than inverter capacity. When you compare quotations, compare kWp with kWp and kW with kW.
Why a bigger inverter is not automatically better
It is tempting to pick the quotation with the largest inverter on the reasoning that it leaves room to add panels later. There are two problems with that.
- Loading. An inverter that is much larger than the array feeding it spends most of the day working well below the range it was designed for.
- Expansion is not plug and play. Adding modules later can mean a new engineering assessment, a fresh submission to Sarawak Energy, additional electrical work and revised protection. Depending on the design, it can still mean replacing the inverter.
If you expect your use to grow, for example with an electric vehicle, say so at the start. It is better to design for that plan openly than to oversize one component and hope.
Why a good specification describes performance, not part numbers
This matters most for organisations that buy through tenders. Module ratings keep rising: a project specified a few years ago around 550 Wp modules may be built when 620 Wp or 650 Wp modules are standard. A different module has different voltage, current and dimensions, which changes the string design.
A specification that fixes "120 units of 550 Wp and two 50 kW inverters" can be out of date before work starts. A specification that states the required capacity and performance, and leaves the supplier to demonstrate how the design meets it, stays valid.
Nine questions to ask about any quotation
- Was my electricity use analysed, and over how many months?
- What share of my use is the system designed to cover?
- What peak sun hours figure was used, and where does it come from?
- Was the roof assessed on site, or from photographs or satellite images?
- How was the array size reached, and what loss factor was applied?
- Why was this inverter size chosen?
- What is the ratio of module capacity (kWp) to inverter capacity (kW)?
- Does the design meet Sarawak Energy's requirements for connection?
- What annual generation does the designer expect, and on what assumptions?
A supplier who can answer these in writing has done the engineering. Compare that work first, and the price second.
A note on Sarawak rules
Sarawak has its own net energy metering scheme, run by Sarawak Energy. It is separate from the schemes in Peninsular Malaysia, and its capacity limits and application steps are different. Limits and forms change, so check the current requirements on Sarawak Energy's net energy metering page before you rely on any figure, including the ones in a quotation. This article was published in November 2026.
Get a sizing you can check
AeanesDaT provides solar design and installation across Sarawak, built with licensed partners. Send us a recent bill and we will show you the assumptions behind our sizing, not only the result.
Try the home solar estimator · Ask for an assessment · Read the Sarawak subsidy guidelines
Ready to Go Solar?
Get a free consultation and customized engineering proposal for your property. Our team in Sarawak is ready to help you transition to clean energy.